{"title":"Kemper","description":null,"products":[{"product_id":"kemper-airwatch-lte-unit-with-6-months-kemper-subscription","title":"KEMPER AIRWATCH LTE UNIT WITH 6 MONTHS KEMPER SUBSCRIPTION","description":"\u003ch4\u003e\u003cstrong\u003eKEMPER AirWatch Air Quality Monitor \u0026amp; 1 Year Kemper Cloud Subscription\u003c\/strong\u003e\u003c\/h4\u003e\r\n\u003cp\u003eThe Kemper AirWatch is a continuous air quality monitor that measures fine dust and fume concentration in real time using a laser-based optical sensor, giving workshops a live, documented view of exposure levels across a production hall, workstation or warehouse — with a full 12 months of cloud reporting included.\u003c\/p\u003e\r\n\u003cp\u003eWhere most fume monitoring is a spot-check exercise, AirWatch runs continuously. It reads particle count and size distribution as PM2.5 and PM10, and shows the result instantly on its own built-in LED display — green, yellow or red — so anyone on the shop floor can see at a glance whether air quality is inside your set limits. Every reading is also logged over mobile network to the Kemper Cloud, where it can be reviewed from a PC, tablet or phone, with adjustable alarm thresholds and full historical data for compliance reporting.\u003c\/p\u003e\r\n\u003cp\u003eAirWatch doesn't just measure — it can act. Connected to Kemper's extraction and room ventilation systems, it drives need-based control, ramping extraction up or down based on actual measured air quality rather than running systems on a fixed timer. That means better protection when fume levels spike, and lower running costs when they don't.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhy it matters under WES-to-WEL\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eWith Australia's shift from Workplace Exposure Standards to Workplace Exposure Limits taking effect from 1 December 2026, and AS\/NZS ISO 21904 already setting the benchmark for LEV system performance, documented, continuous exposure monitoring is moving from best-practice to expected practice. A wall-mounted or portable air monitor with logged, timestamped data is the difference between telling an auditor your extraction works and being able to show them.\u003c\/p\u003e\r\n\u003cp\u003eAirWatch fits that shift directly — it doesn't just capture a fume reading, it retains the record, which is exactly what's needed to demonstrate ongoing compliance rather than a one-off test result.\u003c\/p\u003e\r\n\u003chr\u003e\r\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth\u003eFeature\u003c\/th\u003e\r\n\u003cth\u003eDetail\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMeasurement method\u003c\/td\u003e\r\n\u003ctd\u003eOptical, laser-operated particle sensing\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMeasured parameters\u003c\/td\u003e\r\n\u003ctd\u003eParticle count and size distribution (PM2.5 \/ PM10)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eLocal indication\u003c\/td\u003e\r\n\u003ctd\u003eIlluminated LED area — green \/ yellow \/ red\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eData connectivity\u003c\/td\u003e\r\n\u003ctd\u003eMobile network connection to Kemper Cloud\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRemote access\u003c\/td\u003e\r\n\u003ctd\u003eLive dashboard via PC, smartphone or tablet\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAlarm thresholds\u003c\/td\u003e\r\n\u003ctd\u003eIndividually adjustable limit values and alerts\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSystem integration\u003c\/td\u003e\r\n\u003ctd\u003eCan control connected Kemper room ventilation and extraction systems on a need-based basis\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFleet management\u003c\/td\u003e\r\n\u003ctd\u003eMultiple units manageable via cloud connection\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eIncluded subscription\u003c\/td\u003e\r\n\u003ctd\u003e12 months Kemper Cloud access included from purchase\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTypical applications\u003c\/td\u003e\r\n\u003ctd\u003eIndividual workstations, production halls, logistics halls, warehouses\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003chr\u003e\r\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhat does the Kemper AirWatch actually measure?\u003c\/strong\u003e It measures airborne fine dust and fume particle concentration using an optical laser sensor, reporting both particle count and size distribution as PM2.5 and PM10 — the same particle size categories used in workplace exposure standards.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eHow do I know if air quality is within limits without logging into the app?\u003c\/strong\u003e AirWatch has a built-in illuminated LED indicator on the unit itself that shows green, yellow or red based on your set thresholds, so air quality status is visible at a glance on the shop floor without needing a screen.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eDoes AirWatch require an ongoing subscription?\u003c\/strong\u003e The Kemper Cloud service is included free for the first 12 months from purchase. After that, continued cloud access and remote reporting requires an active subscription — worth confirming renewal pricing with QWS at time of order.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eCan AirWatch automatically control our extraction system, or does it just alert us?\u003c\/strong\u003e Both. On its own it logs and alarms on air quality data. Connected to compatible Kemper ventilation and extraction equipment, it can also drive those systems automatically based on real-time readings — increasing extraction when levels rise and easing off when they don't, rather than running extraction on a fixed cycle regardless of actual conditions.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eIs this suitable for demonstrating compliance under the new WES-to-WEL limits?\u003c\/strong\u003e AirWatch is built for exactly this — continuous, timestamped, cloud-stored monitoring data is what auditors and safety officers need to demonstrate an extraction system is performing, not just installed. It complements (rather than replaces) the LEV system itself, which should already be specified and verified to AS\/NZS ISO 21904.\u003c\/p\u003e\r\n\u003chr\u003e\r\n\u003cp\u003e\u003cstrong\u003eHow AirWatch compares to QWS's other monitoring options\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth\u003eAirWatch (Kemper)\u003c\/th\u003e\r\n\u003cth\u003eAeroGuard\u003c\/th\u003e\r\n\u003cth\u003eALLCLEAR PD30\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eType\u003c\/td\u003e\r\n\u003ctd\u003eFixed area\/room monitor\u003c\/td\u003e\r\n\u003ctd\u003eFixed area monitor\u003c\/td\u003e\r\n\u003ctd\u003ePersonal\/wearable monitor\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBest for\u003c\/td\u003e\r\n\u003ctd\u003eProduction halls, warehouses, multi-workstation areas\u003c\/td\u003e\r\n\u003ctd\u003eIndoor air quality monitoring\u003c\/td\u003e\r\n\u003ctd\u003eIndividual worker exposure tracking\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCloud\/remote reporting\u003c\/td\u003e\r\n\u003ctd\u003eYes — included 12 months\u003c\/td\u003e\r\n\u003ctd\u003eCheck current spec\u003c\/td\u003e\r\n\u003ctd\u003eNo\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eControls extraction automatically\u003c\/td\u003e\r\n\u003ctd\u003eYes (with connected Kemper systems)\u003c\/td\u003e\r\n\u003ctd\u003eNo\u003c\/td\u003e\r\n\u003ctd\u003eNo\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eData logging for compliance\u003c\/td\u003e\r\n\u003ctd\u003eContinuous, cloud-stored\u003c\/td\u003e\r\n\u003ctd\u003eOngoing\u003c\/td\u003e\r\n\u003ctd\u003eWearable session data\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n","brand":"KEMPER","offers":[{"title":"Default Title","offer_id":48183489888407,"sku":"KP-390.220","price":3383.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0301\/8663\/5399\/files\/airwatch-mit-cloud_04b4a1ac-e4d9-4805-b392-025003f76c7a.jpg?v=1788217308"},{"product_id":"kemper-smart-master-3m-flex-arm","title":"KEMPER SMART-MASTER 3M FLEX ARM","description":"\u003ch4 dir=\"ltr\"\u003e\u003cstrong\u003eKemper SmartMaster Mobile Fume Extractor\u003c\/strong\u003e\u003c\/h4\u003e\r\n\u003cp dir=\"ltr\"\u003eThe Kemper SmartMaster is Kemper's entry-level mobile fume extractor — a basic, no-frills unit built for occasional welding with low amounts of smoke and dust. It's the right pick for smaller workshops, maintenance and repair work, or secondary work areas that don't need a high-duty extraction system running constantly, but still need genuine, certified fume capture when welding does happen.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003eDon't mistake \"basic\" for \"under-rated\" — the SmartMaster still carries W3\/IFA certification, meaning it's approved for high-alloy steel welding fume, not just mild steel. The 360°-rotating, swivelling exhaust hood minimises the need for constant arm repositioning, and the whole unit is designed for simple, fast setup.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAvailable arm configurations:\u003c\/strong\u003e 2m or 3m flexible arm as well as a 3m hose \u0026amp; nozzle configurations. Available in 110V and 240V.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cdiv dir=\"ltr\"\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\r\n\u003cth scope=\"col\"\u003eDetail\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter surface\u003c\/td\u003e\r\n\u003ctd\u003e13 m²\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter type\u003c\/td\u003e\r\n\u003ctd\u003eDisposable filter cassette, 3-stage (incl. two pre-filters)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter efficiency\u003c\/td\u003e\r\n\u003ctd\u003e\u0026gt; 99.5%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCertification\u003c\/td\u003e\r\n\u003ctd\u003eW3\/IFA-approved\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eExtraction capacity\u003c\/td\u003e\r\n\u003ctd\u003e950 m³\/h\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMotor power\u003c\/td\u003e\r\n\u003ctd\u003e1.1 kW\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePower supply options\u003c\/td\u003e\r\n\u003ctd\u003e110V \/ 240V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eNoise level\u003c\/td\u003e\r\n\u003ctd\u003e72 dB(A)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm length options\u003c\/td\u003e\r\n\u003ctd\u003e2m \/ 3m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm type\u003c\/td\u003e\r\n\u003ctd\u003eFlexible hose\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMounting\u003c\/td\u003e\r\n\u003ctd\u003eMobile\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBest suited to\u003c\/td\u003e\r\n\u003ctd\u003eOccasional use, low fume\/dust volumes, maintenance and repair work\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003c\/div\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eIs SmartMaster enough for a workshop that welds daily?\u003c\/strong\u003e It's built for occasional use with low dust volumes — a workshop welding daily and generating consistent fume would likely outgrow it quickly. SmartFil or ProfiMaster suit more regular use better.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDoes the entry-level unit still meet stainless steel welding requirements?\u003c\/strong\u003e Yes — SmartMaster still carries the same W3\/IFA approval as the larger units in the range, so it's still rated to handle high-alloy steel fume, just at a lower duty cycle and extraction capacity.\u003c\/p\u003e\r\n\u003chr\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHow the Kemper range compares\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cdiv dir=\"ltr\"\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth scope=\"col\"\u003eCartridge Filter Wall\u003c\/th\u003e\r\n\u003cth scope=\"col\"\u003eMaxiFil Stationary\u003c\/th\u003e\r\n\u003cth scope=\"col\"\u003eProfiMaster\u003c\/th\u003e\r\n\u003cth scope=\"col\"\u003eSmartFil\u003c\/th\u003e\r\n\u003cth scope=\"col\"\u003eSmartMaster\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMounting\u003c\/td\u003e\r\n\u003ctd\u003eWall\/column\u003c\/td\u003e\r\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\r\n\u003ctd\u003eMobile\u003c\/td\u003e\r\n\u003ctd\u003eMobile\u003c\/td\u003e\r\n\u003ctd\u003eMobile\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDuty cycle\u003c\/td\u003e\r\n\u003ctd\u003eContinuous\/non-stop\u003c\/td\u003e\r\n\u003ctd\u003eRegular, medium\u003c\/td\u003e\r\n\u003ctd\u003eFrequent, medium-heavy\u003c\/td\u003e\r\n\u003ctd\u003eRegular, medium\u003c\/td\u003e\r\n\u003ctd\u003eOccasional, low\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter type\u003c\/td\u003e\r\n\u003ctd\u003eSelf-cleaning ePTFE cartridge\u003c\/td\u003e\r\n\u003ctd\u003eSafe-change storage filter (42 m²)\u003c\/td\u003e\r\n\u003ctd\u003eDisposable cassette (17 m²)\u003c\/td\u003e\r\n\u003ctd\u003eDisposable (25 m², 42 m² option)\u003c\/td\u003e\r\n\u003ctd\u003eDisposable cassette (13 m²)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm options\u003c\/td\u003e\r\n\u003ctd\u003e2–7m, flex or rigid, single\/twin\u003c\/td\u003e\r\n\u003ctd\u003e2–7m, flex or rigid\u003c\/td\u003e\r\n\u003ctd\u003e2–4m single, twin-arm available\u003c\/td\u003e\r\n\u003ctd\u003e2–4m, flex or rigid\u003c\/td\u003e\r\n\u003ctd\u003e2–3m flex\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eW3\/IFA (stainless-rated)\u003c\/td\u003e\r\n\u003ctd\u003eYes\u003c\/td\u003e\r\n\u003ctd\u003eYes\u003c\/td\u003e\r\n\u003ctd\u003eYes\u003c\/td\u003e\r\n\u003ctd\u003eYes\u003c\/td\u003e\r\n\u003ctd\u003eYes\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBest for\u003c\/td\u003e\r\n\u003ctd\u003eHigh-volume fixed bays running all day\u003c\/td\u003e\r\n\u003ctd\u003eFixed bays, regular medium-dut\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003c\/div\u003e\r\n\r\n","brand":"KEMPER","offers":[{"title":"Default Title","offer_id":48186932396183,"sku":"KP-64.330","price":4660.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0301\/8663\/5399\/files\/SmartMaster_e9df5fdd-9785-4d3c-b010-0cba6de0677f.png?v=1788232924"},{"product_id":"kemper-smartfil-3m-flex-arm","title":"KEMPER SMARTFIL 3M FLEX ARM","description":"\u003ch4 dir=\"ltr\"\u003e\u003cstrong\u003eKemper SmartFil Mobile Fume Extractor\u003c\/strong\u003e\u003c\/h4\u003e\r\n\u003cp dir=\"ltr\"\u003eThe Kemper SmartFil is a compact, mobile fume extraction unit built for regular welding use with medium fume and dust levels — a genuine middle-ground option between a basic occasional-use extractor and the heavier-duty ProfiMaster. Its standout feature is filter surface: at 25 m² (with a 42 m² high-capacity filter also available), it's larger than most units in its class, translating to a longer run time before the filter needs changing — Kemper rates the standard filter at around 30 reels of 1mm MIG wire before replacement is needed, or roughly double that with the high-capacity option.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003eThe disposable filter changes out completely contamination-free once saturated, and W3\/IFA certification means it's rated for high-alloy and stainless steel fume, not just mild steel. A rotating, swivelling hood with integrated lighting keeps the weld zone visible without extra positioning fuss.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAvailable arm configurations:\u003c\/strong\u003e 2m, 3m or 4m, in either flexible hose or rigid metal-pipe arm styles. Available in 110V, 240V and 415V.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cdiv dir=\"ltr\"\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\r\n\u003cth scope=\"col\"\u003eDetail\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter surface\u003c\/td\u003e\r\n\u003ctd\u003e25 m² standard (42 m² high-capacity option available)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter type\u003c\/td\u003e\r\n\u003ctd\u003eDisposable, contamination-free change\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter efficiency\u003c\/td\u003e\r\n\u003ctd\u003e\u0026gt; 99.5%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCertification\u003c\/td\u003e\r\n\u003ctd\u003eW3\/IFA-approved\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePower supply options\u003c\/td\u003e\r\n\u003ctd\u003e110V \/ 240V \/ 415V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm length options\u003c\/td\u003e\r\n\u003ctd\u003e2m \/ 3m \/ 4m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm type options\u003c\/td\u003e\r\n\u003ctd\u003eFlexible hose or rigid metal pipe\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eExtras\u003c\/td\u003e\r\n\u003ctd\u003eIntegrated hood lighting with on\/off switch\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMounting\u003c\/td\u003e\r\n\u003ctd\u003eMobile\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBest suited to\u003c\/td\u003e\r\n\u003ctd\u003eRegular welding use, medium fume\/dust levels, general fabrication\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003c\/div\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHow long does the SmartFil filter last before it needs changing?\u003c\/strong\u003e Kemper rates the standard 25 m² filter for roughly 30 reels of 1mm MIG wire before replacement; the optional 42 m² high-capacity filter roughly doubles that.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eIs SmartFil suitable for stainless steel?\u003c\/strong\u003e Yes, it's W3\/IFA-approved for the carcinogenic fume produced when welding high-alloy and stainless steels.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWhat's the difference between SmartFil and SmartMaster?\u003c\/strong\u003e SmartFil has nearly double the filter surface (25 m² vs 13 m²) and is rated for regular, more frequent use. SmartMaster is the entry-level option, built for occasional, lighter-duty welding.\u003c\/p\u003e","brand":"KEMPER","offers":[{"title":"Default Title","offer_id":48186945863831,"sku":"KP-64.652.101","price":7742.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0301\/8663\/5399\/files\/SmartFil_Rohrarm.png?v=1788233384"},{"product_id":"kemper-profimaster-twin-3m-flex-arm","title":"KEMPER PROFIMASTER TWIN 3M FLEX ARM","description":"\u003ch4 dir=\"ltr\"\u003e\u003cstrong\u003eKemper ProfiMaster Mobile Fume Extractor\u003c\/strong\u003e\u003c\/h4\u003e\r\n\u003cp dir=\"ltr\"\u003eThe Kemper ProfiMaster is a mobile, trolley-mounted fume extractor built for medium-to-heavy-duty use — the step up from an entry-level mobile unit, aimed at workshops doing frequent MIG\/MAG welding, general fabrication and structural steel work where volumes of fume and dust are genuinely significant. Being mobile rather than wall-fixed, it goes wherever the job is, which suits fabrication shops without a single fixed welding bay.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003eExtraction is rated at 1100–1400 m³\/h depending on configuration, filtering through a 17 m² two-stage filter cassette (main filter plus pre-filter) at above 99% separation efficiency. The 360°-rotating exhaust hood needs minimal repositioning as the welder moves around the piece, and the arm holds its position without extra support. A twin-arm ProfiMaster is also available for two simultaneous work points, with independent dampers on each arm.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAvailable arm configurations:\u003c\/strong\u003e single arm in 2m, 3m or 4m lengths, or twin-arm (2 x 4m); flexible arm as standard. Available in 110V, 240V and 415V.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cdiv dir=\"ltr\"\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\r\n\u003cth scope=\"col\"\u003eDetail\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eExtraction capacity\u003c\/td\u003e\r\n\u003ctd\u003e1100–1400 m³\/h\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter\u003c\/td\u003e\r\n\u003ctd\u003e17 m² disposable filter cassette, 2-stage (main + pre-filter), class E12\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter efficiency\u003c\/td\u003e\r\n\u003ctd\u003e\u0026gt; 99.5%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCertification\u003c\/td\u003e\r\n\u003ctd\u003eW3\/IFA-approved\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMotor power\u003c\/td\u003e\r\n\u003ctd\u003e1.1 kW\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePower supply options\u003c\/td\u003e\r\n\u003ctd\u003e110V \/ 240V \/ 415V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eNoise level\u003c\/td\u003e\r\n\u003ctd\u003e~70–72 dB(A)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm configuration\u003c\/td\u003e\r\n\u003ctd\u003eSingle arm or twin arm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm length options\u003c\/td\u003e\r\n\u003ctd\u003e2m \/ 3m \/ 4m (single); 2 x 4m (twin)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMounting\u003c\/td\u003e\r\n\u003ctd\u003eMobile — trolley-mounted, wheeled\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBest suited to\u003c\/td\u003e\r\n\u003ctd\u003eFrequent, medium-heavy fume\/dust volumes; general fabrication, structural steel\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003c\/div\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eIs the ProfiMaster suitable for stainless steel welding?\u003c\/strong\u003e Yes, it carries W3\/IFA approval for high-alloy steel fume in addition to mild steel and aluminium.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWhat's the difference between ProfiMaster and SmartFil?\u003c\/strong\u003e ProfiMaster has a larger 17 m² filter and higher extraction capacity, aimed at more frequent, heavier fume loads. SmartFil has a bigger filter surface (25 m²) but is pitched at regular rather than heavy-duty use — SmartFil suits general fabrication workshops, ProfiMaster suits shops running structural or heavier MIG\/MAG work more constantly.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCan I get a twin-arm ProfiMaster for two welders?\u003c\/strong\u003e Yes, the twin-arm ProfiMaster (2 x 4m arms) allows two welders to work from the one filter unit, each with independently adjustable extraction.\u003c\/p\u003e","brand":"KEMPER","offers":[{"title":"Default Title","offer_id":48186945896599,"sku":"KP-60.653.DA101","price":9247.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0301\/8663\/5399\/files\/ProfiMaster_2_Arme_rohrausfuehrung.png?v=1788237510"},{"product_id":"kemper-maxifil-stationary-wall-4m-arm","title":"KEMPER MAXIFIL STATIONARY WALL 4M ARM","description":"\u003ch4 dir=\"ltr\"\u003e\u003cstrong\u003eKemper MaxiFil Stationary Wall-Mounted Extraction Unit\u003c\/strong\u003e\u003c\/h4\u003e\r\n\u003cp dir=\"ltr\"\u003eThe Kemper MaxiFil Stationary is a wall-mounted fume extractor built for regular, medium-duty welding use — a step below the continuous-duty Cartridge Filter unit, but still IFA W3-certified for high-alloy steel. It runs a large 42 m² safe-change filter cassette, meaning when the filter does need replacing, it comes out without exposing the operator to trapped dust — a genuine safety difference from open storage filters.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003eAt 1000 m³\/h extraction capacity and a flow-optimised, 360°-rotating exhaust hood that Kemper rates as roughly 40% more effective than a standard round hood, the MaxiFil is built to stay out of the welder's way while still pulling fume at the source. Being wall-mounted, it saves floor space in bays where a mobile trolley unit would be in the way.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAvailable arm configurations:\u003c\/strong\u003e 2m, 3m, 4m, 5m, 6m or 7m, in flexible or rigid metal-tube arm styles.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cdiv dir=\"ltr\"\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\r\n\u003cth scope=\"col\"\u003eDetail\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eExtraction capacity\u003c\/td\u003e\r\n\u003ctd\u003e1000 m³\/h\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter\u003c\/td\u003e\r\n\u003ctd\u003e42 m² safe-change storage filter, non-woven polyester, filter class E12\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter efficiency\u003c\/td\u003e\r\n\u003ctd\u003e\u0026gt; 99.5%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCertification\u003c\/td\u003e\r\n\u003ctd\u003eW3\/IFA-approved\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMotor power\u003c\/td\u003e\r\n\u003ctd\u003e1.5 kW\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePower supply\u003c\/td\u003e\r\n\u003ctd\u003e3 x 400V \/ 50Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eNoise level\u003c\/td\u003e\r\n\u003ctd\u003e72 dB(A)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm length options\u003c\/td\u003e\r\n\u003ctd\u003e2m \/ 3m \/ 4m \/ 5m \/ 6m \/ 7m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm type options\u003c\/td\u003e\r\n\u003ctd\u003eFlexible hose or rigid metal tube\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMounting\u003c\/td\u003e\r\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBest suited to\u003c\/td\u003e\r\n\u003ctd\u003eFixed workstations, regular (not continuous) duty, general and stainless steel welding\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003c\/div\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eIs the MaxiFil suitable for stainless steel welding fume?\u003c\/strong\u003e Yes — it carries W3\/IFA certification, the approval level required for capturing carcinogenic fume from high-alloy\/stainless steel welding, in addition to standard mild steel fume.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHow often does the filter need changing?\u003c\/strong\u003e That depends on hours run and the material being welded, but the 42 m² filter surface gives it a longer service interval than most entry-level wall units, and the safe-change design means the swap doesn't expose the operator to accumulated dust.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDo I need three-phase power for this unit?\u003c\/strong\u003e Yes, the MaxiFil Stationary runs on 3-phase 400V supply — worth checking bay power availability before ordering.\u003c\/p\u003e","brand":"KEMPER","offers":[{"title":"Default Title","offer_id":48186960707735,"sku":"KP-65.850.102","price":10630.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0301\/8663\/5399\/files\/MaxiFil_stationaer_Schlauch.png?v=1788238499"},{"product_id":"kemper-cartridge-filter-wall-unit-4m-arm","title":"KEMPER CARTRIDGE FILTER WALL UNIT 4M ARM","description":"\u003ch4 dir=\"ltr\"\u003e\u003cstrong\u003eKemper Cartridge Filter Wall-Mounted Extraction Unit\u003c\/strong\u003e\u003c\/h4\u003e\r\n\u003cp dir=\"ltr\"\u003eThe Kemper Cartridge Filter Wall-Mounted Extraction Unit is a heavy-duty, continuous-operation fume extractor built for fixed welding stations that run all day, every day. Where most stationary extractors need their filter swapped out periodically, this unit uses a KemTex® ePTFE membrane filter cartridge with automatic, compressed-air-driven self-cleaning — so it keeps working through the shift instead of losing suction as the filter loads up with dust.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003eSeparation efficiency stays above 99.5% even on ultra-fine particles below 0.1 µm, which is why this unit carries W3\/IFA certification for high-alloy and stainless steel welding fume — the carcinogenic nano-particle classification that Australia's shift to Workplace Exposure Limits (WES-to-WEL, effective 1 December 2026) is putting under increasing scrutiny. It mounts straight to a wall or column, taking zero floor space, and is available as a single-arm or twin-arm unit — the twin-arm version has integral dampers so two welders can work simultaneously or alternately with independently adjustable extraction.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAvailable arm configurations:\u003c\/strong\u003e 2m, 3m, 4m, 5m, 6m or 7m, in either flexible hose-style or rigid metal-tube arm — pick the length that reaches your furthest work point without slack, and flexible or rigid depending on how often the arm needs repositioning versus staying set in one position.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cdiv dir=\"ltr\"\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth scope=\"col\"\u003eFeature\u003c\/th\u003e\r\n\u003cth scope=\"col\"\u003eDetail\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter type\u003c\/td\u003e\r\n\u003ctd\u003eKemTex® ePTFE membrane cartridge, automatic compressed-air self-cleaning\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter efficiency\u003c\/td\u003e\r\n\u003ctd\u003e\u0026gt; 99.5%, separates particles below 0.1 µm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCertification\u003c\/td\u003e\r\n\u003ctd\u003eW3\/IFA-approved (suitable for high-alloy\/stainless steel fume)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMounting\u003c\/td\u003e\r\n\u003ctd\u003eWall or column mounted\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm configuration\u003c\/td\u003e\r\n\u003ctd\u003eSingle arm or twin arm (independent dampers)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm length options\u003c\/td\u003e\r\n\u003ctd\u003e2m \/ 3m \/ 4m \/ 5m \/ 6m \/ 7m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArm type options\u003c\/td\u003e\r\n\u003ctd\u003eFlexible hose or rigid metal tube\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDuty cycle\u003c\/td\u003e\r\n\u003ctd\u003eContinuous \/ non-stop operation\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBest suited to\u003c\/td\u003e\r\n\u003ctd\u003eFixed welding bays with high daily duty cycle, mixed or stainless steel work\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003c\/div\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFrequently Asked Questions:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWhat's the difference between this unit and the MaxiFil Stationary?\u003c\/strong\u003e Both are wall-mounted, but this Cartridge Filter unit uses a self-cleaning ePTFE cartridge designed for continuous, non-stop operation without needing to change filters mid-shift. The MaxiFil uses a large safe-change disposable filter cassette instead — well suited to medium, regular use, but not built for the same relentless duty cycle.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCan I run two welders off one unit?\u003c\/strong\u003e Yes, with the twin-arm version — each arm has its own damper, so extraction can be adjusted independently per station whether both welders are working at once or alternating.\u003c\/p\u003e\r\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDoes arm length affect suction performance?\u003c\/strong\u003e Longer arms mean more duct run and slightly more resistance, so match arm length to actual reach needed rather than over-specifying — QWS can advise on the right length for your bay layout.\u003c\/p\u003e","brand":"KEMPER","offers":[{"title":"Default Title","offer_id":48186982891671,"sku":"KP-83.100.102","price":12743.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0301\/8663\/5399\/files\/PF_stat1_schlauch_lang_2_Ausleger_5m.png?v=1788238923"},{"product_id":"kemper-filter-master-xl","title":"KEMPER FILTER MASTER XL","description":"\u003ch4\u003e\u003cstrong\u003eKEMPER FILTERMASTER XL MOBILE FUME EXTRACTOR\u003c\/strong\u003e\u003c\/h4\u003e\r\n\u003cp\u003e\u003cstrong\u003eMobile Fume Extraction Unit with Automatic Filter Cleaning — W3 IFA Certified\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eThe Kemper FilterMaster XL is a mobile, trolley-mounted fume extractor built for high fume loads and continuous operation. It sits above the SmartFil and ProfiMaster in the Kemper mobile range and is the unit for workshops that weld all shift, run stainless or high-alloy steel, or need a mobile extractor that doesn't need its filter pulled and cleaned by hand.\u003c\/p\u003e\r\n\u003cp\u003eAt its core is a 10m² KemTex® ePTFE membrane filter cartridge that separates particles below 0.1 µm at greater than 99.9% efficiency, backed by a timed, automatic rotating-nozzle cleaning system that keeps the filter surface clear during operation. The unit is W3 IFA certified, which means it is approved for extraction of fume from chromium-nickel (stainless) steel welding, the most hazardous fume category under Australia's tightened welding fume exposure limits.\u003c\/p\u003e\r\n\u003cp\u003eThe FilterMaster XL is suited to MIG\/MAG, stick and laser welding on steel, aluminium and stainless, and rolls to the job on a heavy-duty trolley with a flexible arm available in 2, 3 or 4 metre lengths.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth\u003eFeature\u003c\/th\u003e\r\n\u003cth\u003eDetail\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eUnit type\u003c\/td\u003e\r\n\u003ctd\u003eMobile fume extraction and filter unit, trolley-mounted\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eExtraction capacity\u003c\/td\u003e\r\n\u003ctd\u003e1,000 m³\/h\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMax. fan performance\u003c\/td\u003e\r\n\u003ctd\u003e3,000 m³\/h\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMax. vacuum\u003c\/td\u003e\r\n\u003ctd\u003e3,000 Pa\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter\u003c\/td\u003e\r\n\u003ctd\u003e1-stage KemTex® ePTFE membrane cartridge, 10m² surface, surface filtration\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter efficiency\u003c\/td\u003e\r\n\u003ctd\u003e\u0026gt; 99.9% (\u0026gt; 99% of particles \u0026lt; 0.4 µm; separates below 0.1 µm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter cleaning\u003c\/td\u003e\r\n\u003ctd\u003eAutomatic, timed, rotating-nozzle cleaning (compressed air 5–6 bar required)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDust class\u003c\/td\u003e\r\n\u003ctd\u003eM\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCertification\u003c\/td\u003e\r\n\u003ctd\u003eW3 IFA approved — suitable for chromium-nickel \/ high-alloy steel\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWelding processes\u003c\/td\u003e\r\n\u003ctd\u003eMIG\/MAG, Stick (MMA), Laser\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaterials\u003c\/td\u003e\r\n\u003ctd\u003eSteel, aluminium, stainless steel\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDuty\u003c\/td\u003e\r\n\u003ctd\u003eRegular use and non-stop operation, high smoke and particle loads\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eExtraction arm\u003c\/td\u003e\r\n\u003ctd\u003e1 × flexible arm, 150mm diameter, 2m standard (3m and 4m available), rotating flow-optimised hood\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMotor\u003c\/td\u003e\r\n\u003ctd\u003e1.5 kW radial fan\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePower supply\u003c\/td\u003e\r\n\u003ctd\u003e3 × 400V \/ 50Hz, 3.2A rated current\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRotation field control\u003c\/td\u003e\r\n\u003ctd\u003eYes — prevents fan running in reverse on a mis-phased supply\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eNoise level\u003c\/td\u003e\r\n\u003ctd\u003e69 dB(A)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\r\n\u003ctd\u003e643 × 816 × 1,457 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd\u003e173 kg\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhat's Included\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth\u003ePart Number\u003c\/th\u003e\r\n\u003cth\u003eItem\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e62 100 100\u003c\/td\u003e\r\n\u003ctd\u003eFilterMaster XL mobile filter unit with KemTex® ePTFE filter cartridge fitted\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e—\u003c\/td\u003e\r\n\u003ctd\u003e2m flexible extraction arm, 150mm, with rotating extraction hood\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003eReplacement filter cartridge: Kemper 1090438, 10m² KemTex® ePTFE. Using original Kemper filters keeps the W3 certification and warranty intact.\u003c\/p\u003e\r\n\u003cp\u003eOptional: protective mesh for extraction hood (Kemper 1272520); 3m or 4m arm in place of the 2m.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhy Choose the FilterMaster XL?\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eIt cleans its own filter.\u003c\/strong\u003e The rotating-nozzle cleaning system runs on a timer during operation, so extraction performance stays consistent through a full shift instead of tapering off as the cartridge loads. No stopping to knock out or swap filters mid-day.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eCertified for stainless.\u003c\/strong\u003e W3 IFA certification is the highest class for welding fume filter units and is required for chromium-nickel steel fume. If your workshop welds stainless, this is the certification to look for.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eBuilt for continuous duty.\u003c\/strong\u003e Where the SmartFil and ProfiMaster are rated for regular use, the FilterMaster XL is rated for non-stop operation and high fume volumes, with 3,000 m³\/h of fan capacity behind a 1,000 m³\/h extraction rate.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eLess arm fiddling.\u003c\/strong\u003e The flow-optimised rotating hood holds position and captures more at a given distance, so the welder adjusts the arm less and captures more.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eSafe start-up, every time.\u003c\/strong\u003e Rotation field control checks phase sequence at power-up and prevents the fan running backwards on a wrongly wired three-phase outlet, which is a common cause of \"it's on but not pulling\" on site.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eCompliance-ready.\u003c\/strong\u003e With Australia's welding fume workplace exposure limit now at 1 mg\/m³ and AS\/NZS ISO 21904 the reference standard for extraction equipment, a certified, high-efficiency source-capture unit is the practical way to demonstrate control at the point of generation.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhere the FilterMaster XL sits in the Kemper mobile range\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth\u003eSmartFil\u003c\/th\u003e\r\n\u003cth\u003eProfiMaster\u003c\/th\u003e\r\n\u003cth\u003eFilterMaster XL\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDuty rating\u003c\/td\u003e\r\n\u003ctd\u003eRegular use, medium fume\u003c\/td\u003e\r\n\u003ctd\u003eMedium-to-heavy duty\u003c\/td\u003e\r\n\u003ctd\u003eNon-stop operation, high fume\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFilter cleaning\u003c\/td\u003e\r\n\u003ctd\u003eManual \/ disposable \u003cstrong\u003e[verify]\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003eManual \/ disposable \u003cstrong\u003e[verify]\u003c\/strong\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003eAutomatic rotating nozzle\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eW3 certified\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003e[verify]\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003e[verify]\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eYes\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eExtraction capacity\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003e[verify]\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003e[verify]\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e1,000 m³\/h\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eArms\u003c\/td\u003e\r\n\u003ctd\u003e1 × 3m\u003c\/td\u003e\r\n\u003ctd\u003e1 or 2 × 3m\u003c\/td\u003e\r\n\u003ctd\u003e1 × 2m \/ 3m \/ 4m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCompressed air needed\u003c\/td\u003e\r\n\u003ctd\u003eNo\u003c\/td\u003e\r\n\u003ctd\u003eNo\u003c\/td\u003e\r\n\u003ctd\u003eYes, 5–6 bar\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBest for\u003c\/td\u003e\r\n\u003ctd\u003eLight fabrication, single bay\u003c\/td\u003e\r\n\u003ctd\u003eBusy fab shop, shared bays\u003c\/td\u003e\r\n\u003ctd\u003eStainless, high-alloy, all-day production\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eIs the Kemper FilterMaster XL suitable for stainless steel welding fume?\u003c\/strong\u003e Yes. The FilterMaster XL is W3 IFA certified, the certification class required for extracting fume from chromium-nickel (stainless) steel, where hexavalent chromium and nickel compounds are the primary hazard.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eHow does the automatic filter cleaning work?\u003c\/strong\u003e A rotating compressed-air nozzle inside the cartridge cleans the KemTex® ePTFE filter surface on a timed cycle while the unit is running. It needs a 5–6 bar compressed air supply. Cleaned dust falls into a collection tray for disposal.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eDoes the FilterMaster XL need three-phase power?\u003c\/strong\u003e Yes. It runs on 3 × 400V 50Hz and draws 3.2A. Rotation field control protects against incorrect phase sequence.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhat's the difference between extraction capacity and fan performance?\u003c\/strong\u003e Extraction capacity (1,000 m³\/h) is the rated airflow at the arm hood in normal use. Max. fan performance (3,000 m³\/h) is the fan's capacity with the filter clean and no arm restriction. The margin is what keeps extraction consistent as the filter loads.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhat arm lengths are available?\u003c\/strong\u003e 2m is standard, with 3m and 4m options. All are 150mm diameter flexible arms with a rotating extraction hood.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eHow often does the filter need replacing?\u003c\/strong\u003e With automatic cleaning, the cartridge lasts considerably longer than a manually cleaned filter, but replacement interval depends on fume load and material. Replacement is the Kemper 1090438 10m² cartridge; using the original filter keeps the W3 certification and warranty valid.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eDoes the FilterMaster XL meet Australian welding fume requirements?\u003c\/strong\u003e It's a W3-certified, \u0026gt;99.9% efficiency source-capture unit, which is the equipment class Australian guidance points to for controlling welding fume at the source under the current exposure limit. Talk to the QWS team about matching it to your process, hours and material mix.\u003c\/p\u003e","brand":"KEMPER","offers":[{"title":"Default Title","offer_id":48274233262231,"sku":"KP-62.100.101","price":11894.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0301\/8663\/5399\/files\/FilterMaster_XL_eb26b4e4-e3b8-4261-81b1-794ac4263b61.png?v=1789607457"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0301\/8663\/5399\/collections\/FilterMaster_XL.png?v=1788217457","url":"https:\/\/www.weldingsupply.com.au\/collections\/kemper.oembed","provider":"QWS - Welding Supply Solutions","version":"1.0","type":"link"}